3-way Fire Brigade Inlet (also called a Pumping In Breech) allows Fire Tenders (Pumpers) to pump in water into the dry riser/wet riser/sprinkler system piping using external water sources such as hydrants. Therefore, it ensures a quick and reliable water supply during emergencies. A 3-way fire brigade inlet is fitted with the required number of standard male instantaneous inlets to feed the riser pipe depending upon size.
VariEX Fire Brigade Inlet (Pumping in Breech), having a cast iron body with 3 Nos, 63 mm size SS male instantaneous inlets (with NRV) and 80 mm size flanged outlet, suitable for connection to dry riser piping. Additionally, the inlet includes a drain valve to remove water after operation, keeping the system ready for the next use.
Inspect the inlet valve twice a year
Check for leaks, rust, corrosion, and wear
Remove dirt and debris
Use a soft cloth and mild detergent
Apply valve grease to moving parts
Ensure smooth operation
Open and close the valve
Verify pressure is 10–16 bar
Replace worn gaskets
Tighten connections
Log inspections and repairs
Comply with fire safety regulations
Expertly Engineered: Designed by fire safety professionals for reliable emergency performance
Certified Quality: Complies with IS: 5290-1992 and CE standards
Durable Build: Manufactured using high-grade stainless steel / cast iron
Easy to Use: Smooth valve operation with standard fire brigade hose compatibility
Low Maintenance: Corrosion-resistant finish for long service life
Trusted Support: Backed by clear documentation and after-sales assistance
A Variex 3-way fire brigade inlet is used to connect the fire brigade’s external water supply to a building’s internal fire hydrant system during emergencies.
It is installed on the outer wall of a building, making it easily accessible for firefighters.
Variex fire brigade inlets are manufactured in accordance with IS: 5290-1992 and CE safety standards.
The fire brigade hose is connected to the inlet, the valve is opened to allow water flow and closed securely after use.
Routine inspection and functional testing should be carried out every six months to ensure reliable operation.
Our working process for refilling the fire extinguisher is focused on an interactive environment with our valued clients. We understand the value of time of services and strive hard to fulfill the clients’ requirements in a scheduled time frame. We at Varistor adopt in utilizing new technologies that are capable of providing maximum results during the refilling service. The 3 steps followed by us during fire extinguisher’s refilling service are as follows:
Pick up the empty extinguisher from customer’s place
Refill the extinguisher with appropriate material using quality equipment and after that do check it with our professionals before delivery to the client’s destination
Delivers the filled extinguishers to the client’s place on time